Universal temperature transmitter The isolated transmitter is able to execute many functions such as measure and linearisation of the temperature characteristic of RTDs sensors, conversion of a voltage signal. The measured values are converted in a 4-20 mA current signal. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
Temperature transmitter for RTDs The transmitter is designed to provide on output a 4-20 mA current loop linearised signal proportional with the temperature characteristic provided from the Pt100 connected to its input. It is possible to connect on input both 3 wires and 2 wires sensors. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
Temperature transmitter for thermocouple The transmitter is designed to provide a 4-20 mA output on current loop linear and proportional with the value of voltage generated from the thermocouple connected to its input, execute the linearisation of the input signal. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
Unified signal repeater The transmitter is a passive 0-20 mA current loop isolator. The input current, variable from 0 up to 20 mA, is converted in an output current of the same value but keeping a galvanic isolation from the input circuit. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
Unified signal repeater for hazardous area (ATEX) Is device is a galvanic isolated Intrinsically Safety Barrier, defined as "Associated Apparatus". The input is 0-20 mA or 4-20 mA, output is 0-10V or 2-10V or current signal 0-20mA or 4-20mA. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
  MODULES FOR CONVERSION, ACQUISITION AND CONTROL
Converters RS232-RS485/422, USB-RS485, Modbus TCP/RTU The devices is an isolated interface converter between RS 232-RS 485/RS 422; USB-RS 482/RS 422; Modbus TCP-Modbus RTU; Repetor izolat galvanic RS 485/RS 422, with a baud-rate transmission up to 115.2 Kbps Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
Acquisition isolated modules The device converts the analog signal applied on the input in engineering units in digital format. It is possible to connect on input RTD sensor, resistance, thermocouples, voltage signal up to ± 10 V and current up to ± 20 mA. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
Control isolated modules The device is able to acquire, the data are transmitted with MODBUS RTU/ASCII protocol on RS-485 network. To assure safe operation of the system, the device is equipped with two Watch-Dog timers. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
A/D isolated interfacefor PLC The devices are an evolution in the techniques of connection of analogue signals to PLC. The devices of this series amplify, linearise, isolate, filter and convert the analogue signals coming from various sensors in a high resolution digital signal. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172
  POWER SUPPLY
Power supply The universal AC line input switching power supply unit is designed to provide up to 1A at 24 Vdc regulated voltage, is in compliance with the Directive 2004/108/EC on the Electromagnetic Compatibility and Directive 2006/95/EC on the Electric Safety. Details Mail Tel/Fax: +40 232760951 Mobile: +40 0744592172